SCHURTER has expanded its line of power input modules with a version without a grounding plug for protection against electric shock in Class II double insulation applications. KMF power input modules have been widely used to protect Class I equipment due to their compact package design and high performance. The new protection class II products are suitable for home medical equipment, home medical equipment medical specification using electric shock protection class II design.
The new KMF anti-shock protection class II products are designed in accordance with IEC 60320-1 C18. This product is especially suitable for medical devices in accordance with IEC 60601-1-11, which specifies a range of additional safety precautions for home medical devices. As the world's population ages and medical costs continue to rise, the demand for home medical equipment is also increasing. Protection Class II devices typically do not have a metal casing when compared to Class I equipment. This type of equipment is also known as double insulated equipment and has higher safety requirements for live parts than exposed parts. KMF Protection against Electric Shock Class II power input modules provide double insulation between live and exposed components. This reinforced insulation passes the 4000 VDC withstand voltage test applied between the live conductor (L) and the neutral conductor (N) compared to the mounting plate.
Power input module
The KMF line switch consists of a 2-pole line switch and a 1- or 2-pole fuse holder. For medical applications, an “extra safety†fuse holder can only be opened with the use of other tools. EMC filters are available for medical devices and low leakage (M5) models. This filter integrated in the power input module effectively suppresses interference and improves electromagnetic compatibility. The rated current range is 1A to 10A at 250 VAC. The wiring method is completed by the quick plug terminal 4.8 × 0.8 mm.
KMF anti-shock protection Class I and Class II are certified by ENEC, cURus and CCC. These two levels of protection are suitable for use in other equipment in accordance with IEC 60601-1-11, IEC 60950 and IEC 60601-1.
Technical data sheet:
- IEC C18 power input connector with 2-pole switch, 2-pole fuse holder and a filter
- M5 medical filter
- Rated current: 1A, 2A, 4A, 6A, 10A (ENEC/UL/CSA, CCC) at 40 °C
- Management unit installation 1.0 - 2.5 mm
- Lead connector 4.8 x 0.8 mm
application:
- Suitable for fully insulated equipment in accordance with IEC 61140
- Suitable for medical devices in accordance with IEC 60601-1
- Particularly suitable for home medical devices in accordance with IEC 60601-1-11