Interleukin-1 ( IL-1 ) ELISA Kit User Manual
This reagent is for research use only. Specimen: serum or plasma
Ancient flower supply
Purpose of use: This kit is used to determine the content of interleukin-1 (IL-1) in serum, plasma and related liquid samples.
Test principle:
The IL-1 kit is a solid phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards of known IL-1 concentrations and samples of unknown concentration are added to the microplates for detection. IL-1 and biotinylated antibodies were first incubated simultaneously. After washing, avidin-labeled HRP was added. After incubation and washing, the unbound enzyme conjugate is removed, then the substrates A, B, and the enzyme conjugate are added simultaneously. Produce color. The depth of the color is proportional to the concentration of IL-1 in the sample.
The performance of kit:
1 sensitivity: minimum detection concenIL-1ation is less than 1 standard. LiIL-1arity of dilution. Sample liIL-1ar regression and the expected concenIL-1ation correlation coefficient R value is 0.990.
2: no specific reaction with other cytokiIL-1s.
3 repeaIL-1ility: plate, plate between the coefficients of variation were less than 10%.
Interleukin-1 kit, elisa kit instructions, ELISA kit, ELISA kit, elisa kit instructions
Kit content and its preparation
Kit components (2-8 ° C) | 96-well configuration | 48 hole configuration | Formulation |
96/48 ELISA plate | 1 board (96T) | Half board (48T) | Ready-to-use |
Plastic diaphragm cover | 1 block | Half block | Ready-to-use |
Standard: 80ng/ml | 1 bottle (0.6ml) | 1 bottle (0.3ml) | According to the instructions for thinning |
Blank control | 1 bottle (1.0ml) | 1 bottle (0.5ml) | Ready-to-use |
Standard dilution buffer | 1 bottle (5ml) | 1 bottle (2.5ml) | Ready-to-use |
Biotinylated anti-IL-1 antibody | 1 bottle (6ml) | 1 bottle (3.0ml) | Ready-to-use |
Affinity chain enzyme-HRP | 1 bottle (10ml) | 1 bottle (5.0ml) | Ready-to-use |
Washing buffer | 1 bottle (20ml) | 1 bottle (10ml) | Dilute according to the instructions |
Substrate A | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Substrate B | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Stop solution | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Specimen dilution | 1 bottle (12ml) | 1 bottle (6.0ml) | Ready-to-use |
Self-contained materials
1. Distilled water.
2. Sampler: 5ul, 10ul, 50ul, 100ul, 200ul, 500ul, 1000ul.
3. Oscillators and magnetic stirrers, etc.
safety
1. Avoid direct contact with the stop solution and substrates A, B. Once exposed to these liquids, rinse with water as soon as possible.
2. Do not eat, drink, smoke or use cosmetics during the experiment.
3. Do not use your mouth to take any ingredients from the kit.
Operational precautions
1. Reagents should be stored according to the label instructions and returned to room temperature before use. Standards after dilution should be discarded and cannot be stored.
2. The slats not used in the experiment should be immediately put back into the bag and sealed to prevent deterioration.
3. Other reagents not used should be packaged or covered. Do not mix reagents of different batches. Use before warranty.
4. Use a disposable tip to avoid cross-contamination. Avoid pipettes with metal parts when drawing stop solution and substrate A and B.
5. Use a clean plastic container to configure the wash solution. Mix all the ingredients and samples in the kit thoroughly before use.
6. Wash the enzyme plate should be fully patted dry, do not put the absorbent paper directly into the enzyme standard reaction well to absorb water.
7. Substrate A should be volatilized to avoid opening the lid for extended periods of time. Substrate B is sensitive to light and avoids prolonged exposure to light. Avoid contact with hands and be toxic. The OD value should be read immediately after the experiment is completed.
8. The order of addition of reagents should be consistent to ensure that all wells are incubated for the same time.
9. The incubation was carried out according to the time indicated in the instructions, the amount of addition and the order.
Sample collection, processing and storage methods
1. Serum ---- Avoid any cell irritation during the procedure. Use tubes without pyrogens and endotoxins. After collecting the blood, the serum and red blood cells were quickly and carefully separated by centrifugation at 1000 x g for 10 minutes.
2, plasma ----- EDTA, citrate, heparin plasma can be used for testing. The pellet was removed by centrifugation at 1000 x g for 30 minutes.
3. Cell supernatant - 1000 x g was centrifuged for 10 minutes to remove particles and polymer.
4, tissue homogenate ----- the tissue is added to the appropriate amount of physiological saline mash. Centrifuge at 1000 × g for 10 minutes, take the supernatant
5. Storage ------If the sample is not used immediately, it should be divided into small parts - 70 °C to avoid repeated freezing. Do not use hemolysis or hyperlipemia as much as possible. If there are large amounts of particles in the serum, centrifuge or filter before testing. Do not heat thaw at 37 ° C or higher. It should be thawed at room temperature and ensure that the sample is fully thawed evenly.
2. Dilution of wash buffer (50 x): 50-fold dilution of distilled water.
Steps
1. Mix all reagents thoroughly before use. Do not allow the liquid to generate a large amount of foam, so as to avoid adding a large amount of air bubbles during the loading, resulting in errors in the loading.
2. The number of slats required is determined by the number of samples to be tested plus the number of standards. Multiple holes are recommended for each standard and blank hole. Each sample is determined according to its own quantity, and it is possible to use the double hole as much as possible to make a double hole. The specimen was diluted 1:1 with the specimen dilution and 50 ul was added to the reaction well.
3. 50 ul of the diluted standard was added to the reaction well, and 50 ul of the sample to be tested was added to the reaction well. Immediately add 50 ul of biotinylated antibody. Cover the membrane, mix gently by shaking, and incubate for 1 hour at 37 °C.
4. Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
5. 80 ul of affinity streptavidin-HRP was added to each well, and the mixture was gently shaken and incubated at 37 ° C for 30 minutes.
6. Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
7. Add 50 μl of each of the substrates A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid lighting.
8. Remove the microplate and quickly add 50 ul of stop solution. Immediately after adding the stop solution, the results should be determined.
9. The OD value of each well was measured at a wavelength of 450 nm.
Limit
The results above the No. 6 standard are non-linear and no accurate results can be obtained from this standard curve.
Interleukin-1 ( IL-1 ) ELISA kit performance
1. Sensitivity: The minimum detection concentration is less than the No. 1 standard. The linearity of the dilution. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value was 0.990.
2. Specificity: Does not react with other cytokines.
3. Repeatability: The coefficient of variation between the plate and the plate is less than 10%.
Result judgment and analysis
1. Instrument value: read the OD value of each hole on a microplate reader with a wavelength of 450 nm.
2. The absorbance OD value is the ordinate (Y), and the corresponding IL-1 standard concentration is the abscissa (X), and the corresponding curve is obtained. The IL-1 content of the sample can be converted from the standard curve according to the OD value. The corresponding concentration.
3. Detection range: 0-80ng/ml
4. Sensitivity: 0.1 ng/ml
We have a variety of designs for Intercom System With Tuya, different sizes, different keys, etc., you can refer to our pictures,
We have been focusing on independent research and development of intercom system with tuya
since 2011. We have professional reach and devolve team to serve you, and we can provide you with professional products and services, If you need more information about our factory or intercom system, please do not hesitate to contact us, we are very honored to share catalog with you.
Smart doorphone with tuya is an intercom system that can be connected to a mobile phone. The system adopts a unified TCP/IP networking architecture to connect all-digital video intercom, security equipment and elevator linkage system. At the same time, it can be connected to the central management machine. The property community can better manage tenants, improve user experience and property services, etc. They use POE switches to connect multiple indoor units and video door phones, and POE switches supply power to the indoor units. The wiring is very simple and convenient, and the overall cost is low.
Smart doorphone with tuya improves user experience, because users can receive call information, and can monitor Video Door Phone at any time through tuya application, even if users are in an office, picnic or travel, they can immediately receive call information from visitors , and talk to them, you can also monitor visitors. If it is the user's friend, it can also remotely unlock the visitor on the mobile phone, which is very convenient.
The video doorphone in the picture is the most popular model from our company - MK-AZZJ4C, we have adopted the embedded design, which is very classic and beautiful. It is also an Android system, which can support simultaneous connection of multiple indoor units and mobile phones to realize remote monitoring, calling and unlocking on the mobile phone. We have also added the function of face recognition and LED fill light, which can clearly monitor and unlock using face recognition even at night. Ideal for multi-apartment, hotel and community applications.
The following are the parameters of MK-AZZJ4C for your reference:
1. 4.3 inch 720 HD display TCP/IP Intercom system
2. Calling, intercom, unlocking, monitoring
3. High quality aluminium alloy frosted panel + high-end glass lens + sensor buttons
4. Digital camera, stable and clear image shooting
5. Night vision and bright light compensation function
6. Full duplex voice intercom, comparable to ordinary telephone intercom
7. Android system ,ARM CPU, TUYA App (support Android and IOS system)
8. LPDDR3 1 GB memory, standard EMMC 8 GB storage expandable
9. RJ45 standard ethernet interface all-digital design
10. Low power consumption technology solution, saving energy and long life span
11. Dimension:400*140*51(mm)
12. Install method : Wall/flush install (390*130*46 mm)
13. Image/video advertising playback (advertising can be customized)
14. Door opening:IC/ID card/ password/ face recognition/ mobile phone
Our company has been focusing on intercom system for 11 years, we can provide you with different systems, like IP, 2 wire and 4 wire system, and we are also OEM & ODM factory, support to customize your brand and function, Thank you very much for your interest in our products, if you need more detailed information, please feel free to contact me.
Smart Doorphone With Tuya,Tuya Smart Doorbell,Tuya Video Doorbell,Tuya Smart Video Doorbell
Zhuhai Mingke Electronics Technology Co., Ltd , https://www.mingke-tech.com